A Rack-Mount PLC (Planar Lightwave Circuit) splitter is an optical splitter used in passive optical networks (PONs) to divide a single optical signal into multiple outputs. The rack-mount design is specifically intended for installation in a standard 19-inch rack to fit into a data center or telecommunication facility. The rack-mount PLC splitter uses a planar waveguide circuit to distribute the optical signal evenly across the output ports, minimizing signal loss and ensuring uniform power splitting. The rack-mount design typically allows the splitter to be installed in multiple configurations, such as 1U, 2U, 3U, or 4U form factors, to meet high-density fiber-optic requirements. The splitter’s connectors are typically positioned at the front of the unit to make it easier to attach and detach input and output fibers. Rack-mount PLC splitters are commonly used in various fiber optic applications such as FTTx (fiber-to-the-x), Data Center and Enterprise networking, and Telecommunications applications. These splitters come in various configurations, such as 1x2, 1x4, 1x8, 1x16, 1x32, and 1x64 to meet different networking requirements.
Uniform power splitting
Compact package dimension
Low polarization dependent loss
Good channel-to-channel uniformity
Low Insertion Loss and high Return Loss
Environmentally and mechanically stable
Wide operating wavelength range from 1260nm to 1650nm
Specification:
Port Configuration | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
Operating Wavelength (nm) | 1260~1650 | |||||
Insertion Loss (dB) | 4.5 | 8.1 | 11.6 | 15.0 | 18.0 | 21.5 |
Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 2.0 | 2.5 | 2.5 |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Fiber Length (m) | 1.0 or customized | |||||
Fiber Type | G657A or customized | |||||
Wavelength Dependent Loss (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Stability (-40~+85°C) (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Operating Temperature (°C) | -40~+85°C | |||||
Storage Temperature (°C) | -40~+85°C |
Note: All measurements are done at room temperature with connectors.
Input Channel Number | Input Optical | Output Channel Number | Output Optical | Connector Type In/Out | Fiber | Package |
1=1channel | 0=250um bare fiber | 02=2 channel | 0=250um bare fiber | 0=no connector | 10=1.0 meter | 1=S.S Tube 1 |